Equipment for soil treatment
Combined steel solid fuel boiler with cooking function AKTV-16
New
Top
Designed for heating individual residential houses and communal facilities equipped with a water heating system with natural or forced circulation of the coolant. The units are also intended for cooking. Coal of class 25…50 mm is used for operation. The duration of the operating cycle is at least 12 hours.
Description of Equipment
| Parameter name | Unit | AKTV-16 |
|---|---|---|
| 1. Rated heat output, ±15% | kW | 16 |
| 2. Fuel type, DSTU 3472-96 | - | Hard coal, anthracite |
| 3. Rated fuel consumption | kg/h | Hard coal: 4.3 Anthracite: 2.8 Firewood: 9.4 |
| 4. Efficiency, not less than | % | Hard coal: 65 Anthracite: 75 Firewood: 60 |
| 5. Maximum water temperature at the outlet, not more than | °C | 95 |
| 6. Water volume of the unit, not more than | l | 38 |
| 7. Draught behind the unit, ±2 | Pa | 8 |
| 8. Temperature of combustion products, not less than | °C | 140 |
| 9. Operating water pressure at the outlet, not more than | MPa | 0.2 |
| 10. Overall dimensions, not more than | mm | Length: 1034 Width: 548 Height (to the cooking plate): 850 |
| 11. Weight, not more than | kg | 150 |
| 12. Diameters of connection pipes to the heating system (with natural circulation) | thread | G2” |
| 13. Mean time between failures, not less than | h | 22000 |
| 14. Average service life, not less than | years | 15 |
| 15. Heated room volume | m³ | 480 |
Specifications of Equipment