• Ru
  • En
  • Ua
Callback

The boiler combined solid steel AKTV-16

Designed for heating individual houses, buildings communal household purpose equipped with system of water heating with natural or forced circulation of coolant. Apparatus are also designed for cooking. To operate using coal class 25 … 50mm. The working cycle for at least 12 hours.

Name

Units of physical values

Reference designation

value

AKTV – 16

1 Rated calorific power, ± 15%

kW

16

2 Fuel, DSTU 3472-96

 

Coal, anthracite

3 Rated fuel consumption

        – coal

        – anthracite

        – firewood

kg / h

 

4,3

2,8

9,4

4 The efficiency of not lower than

        – Coal

        – anthracite

        – firewood

%

 

65

75

60

 

5 The maximum temperature of the outlet water from the apparatus, not more than

оС

95

 

6 Water amount are not more than

l

38

7 Vacuum because the device, ± 2

8

8 Flue gas temperature is not less than

оС

140

9 Operating pressure of water at the outlet of the apparatus, no more

МPа

0,2

10 Dimensions, more

  – length

  – width

  – height to varichnoi plate

mm

 

1034

548

850

11 Weight,

kg

150

12 The diameters of the pipes connecting to the heating system (natural circulation)

 

thread

 

G2”

 

13 Mean time to failure, at least

hours

22000

14 Average service life, not less

15 The volume of the heated space

Year

m3

15

480

X